<< Click to Display Table of Contents >> Concrete Information Tab |
This tab is used to specify the information for the concrete specimens.
The following can be entered and displayed on this tab:
Information
Loading Type: This is the type of loading applied to the specimen. It can either be third-point or center-point.
Specimen Type: This is used to select the type of specimen. It can either be cast cylinder, cored cylinder, or concrete cube.
Specify Dates: Check this box to specify the batch, pour, and test dates (the test dates are specified on the Data & Results tab).
Batch Date: If the Specify Dates box is checked, this is used to specify the date and time the concrete was batched.
Pour Date: If the Specify Dates box is checked, this is used to specify the date and time the concrete was poured.
Supplier: This is used to select the concrete supplier from a predefined list of suppliers. To get detailed information about the supplier click on the button on the right.
Mix Design ID: This is used to select the mix design ID from a predefined mix designs. A datasheet showing the details of the mix design can be displayed by clicking on the button on the right.
Orientation: This is used to specify the orientation of the loading relative to the specimens.
Moisture Condition: This is used to specify the moisture condition of the specimens at the time of testing.
Gap Adjustments: This is used to select any gap adjustments that were applied to the specimens.
Curing History: This is used to describe the curing history of the specimens.
Units
Length Units: This is used to select the units for length.
Load Units: This is used to select the units for load.
Strength Units: This is used to select the units for strength.